Microscopy, Imaging, and Flow Cytometry Equipment

Leica Thunder Live Cell 3D microscope

  • TIRF and Photomanipulation Modules
  • High power TIRF for super resolution single molecule localization microscopy
  • Automated Leica DMI8 microscope with incubator for environmental control
  • LED8 for epi-illumination, DIC and phase contrast capable
  • Hamamatsu Flash 4.0 v3 camera
  • Gemini camera mount for simultaneous 2-channel imaging (Em 520/40 and 605/70)
  • Laser excitation wavelengths:  405, 488, 561, and 638 nm
  • 350 nm Pulsed Laser Unit
  • Objectives:  5x/0.12 PH0, 10x/0.32 PH1, 20x/0.40 corr PH1, 20x/0.80 oil DIC PLU, 63x/1.2 w corr uvis DIC cs2 PLU, 100x/1.47 oil corr DIC TIRF, 160x/1.43 TIRF/GSD
  • Advanced LASX software features including:  THUNDER computation clearing, Navigator with tile scanning and multi-position experiments, 3D Analysis, and 3D Visualization Advanced

Please credit the National Institutes of Health Shared Instrument Grant program "NIH 1S10OD028515-01" when citing use of this instrument.

Leica Thunder Live Cell 3D microscope

Leica TCS SP5 confocal microscope

  • Automated Leica DMI 6000 microscope with 2.5x/0.07 pl fl, 10x/0.3 hc pl fl, 40x/1.25 oil hcx pl apo cs, 63x/1.4 oil hcx pl apo cs objectives.
  • Laser excitation wavelengths: 405, 458, 476, 488, 496, 514, 543, 594, and 633 nm
  • Acousto-Optical Beam Splitter
Leica TCS SP5 confocal microscope

MMI Laser capture microdissection system

  • Automated Olympus IX81 microscope with 4xPhL/0.13 uplfln, 10xPh1/0.3 uplfln, 20xPh1/0.45 lucplfln (0-2), 40xPh2/0.6 lucplfln, and 60xPh2/0.7 objectives
  • Laser cutting capabilities (MMI Cell Cut Plus) with mini caplift technology
  • MMI CellEctor Plus capillary based sorting system for cells in suspension
MMI Laser capture microdissection system

Olympus time-lapse system

  • Automated Olympus IX81 microscope with 4x/0.13 uplfln, 10x/0.3 uplfln, 20xPh1/0.5 uplfln, 40x/0.95 uplsapo (0.11-0.23) and 60x/1.35 oil uplsapo objectives.
  • Environmental chamber with CO2, O2, and temperature control
Olympus time-lapse system

Xenogen IVIS Lumina

  • Fluorescence /luminescence in vivo/ in vitro imaging
  • Sensitive detection of low emission light
Xenogen IVIS Lumina

Olympus IX71 microscope

  • Inverted microscope with 10xPh1/0.3 uplfln, 20xPh1/0.45 lucplfln, 40xPh2/0.6 lucplfln, 60x/1.35 oil uplapo objectives
  • Q imaging Retiga 2000R CCD monochrome and MF603C 6MP CCD color cameras
Olympus IX71 microscope

Zeiss Axioplan microscope

  • Upright microscope with 10xPh1/0.3 pl nf, 20xPh2/0.5 pl nf, 40xPh2/0.75 pl nf, 63x/1.4 oil pl apo, and 100x/1.3 oil pl nf objectives
  • Coolsnap CCD color camera
Zeiss Axioplan microscope

Nikon Diaphot microscope

  • Inverted microscope with 10xPh1/0.3 pl nf, 20xPh2/0.5 pl nf, 40xPh2/0.75 pl nf, 63x/1.4 oil pl apo, and 100x/1.3 oil pl nf
  • Microfire CCD color camera
Nikon Diaphot microscope

BD Accuri C6 flow cytometer

  • 2-laser-4-color analyser
  • 488 nm and 640 nm laser lines
  • Csampler for autosampling from 48- and 96-well plates
BD Accuri C6 flow cytometer

BD LSR Fortessa flow cytometer

  • 4-laser-16 color analyser
  • 405, 488, 561, and 640 nm laser lines
  • HTS for high-throughput sampling from 96-well plates
BD LSR Fortessa flow cytometer

  • Metamorph ( processing of microscopy images)
  • FlowJo (processing of flow cytometry data)